  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current6A
Built-in depth82.5mm
Release characteristicOther
Rated impulse withstand voltage Uimp8kV
Frequency0 - 0Hz
Power loss7.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui1500V
Number of protected poles4
Rated voltage-V
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class3
Flush-mounted installationYes
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings6
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030029R0001 | S804S-UCK6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Built-in depth

82.5mm

Release characteristic

Other

Rated impulse withstand voltage Uimp

8kV

Frequency

0 .. 0Hz

Power loss

7.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

1500V

Number of protected poles

4

Rated voltage

-V

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

3

Flush-mounted installation

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

6

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof