Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Explosion-proofNo
Rated current1A
Rated voltage-V
Voltage typeOther
Over voltage category3
Connectable conductor cross section solid-core0 - 70mm²
Rated insulation voltage Ui1500V
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 50mm²
Width in number of modular spacings4.5
Power loss4.8W
Release characteristicOther
Frequency0 - 0Hz
Built-in depth82.5mm
Ambient temperature during operating-25 - 60°C
Pollution degree2
Number of protected poles3
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Number of poles (total)3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030041R0001 | S803S-UCB1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Explosion-proof

Rated current

1A

Rated voltage

-V

Voltage type

Other

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 70mm²

Rated insulation voltage Ui

1500V

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 50mm²

Width in number of modular spacings

4.5

Power loss

4.8W

Release characteristic

Other

Frequency

0 .. 0Hz

Built-in depth

82.5mm

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Number of protected poles

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Number of poles (total)

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.