Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicOther
Built-in depth82.5mm
Rated insulation voltage Ui1500V
Rated impulse withstand voltage Uimp8kV
Rated voltage-V
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency0 - 0Hz
Number of protected poles3
Power loss6.6W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated current2A
Flush-mounted installationYes
Pollution degree2
Width in number of modular spacings4.5
Over voltage category3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030042R0001 | S803S-UCB2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Other

Built-in depth

82.5mm

Rated insulation voltage Ui

1500V

Rated impulse withstand voltage Uimp

8kV

Rated voltage

-V

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

0 .. 0Hz

Number of protected poles

3

Power loss

6.6W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated current

2A

Flush-mounted installation

Pollution degree

2

Width in number of modular spacings

4.5

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.