Rated voltage-V
Rated insulation voltage Ui1500V
Number of poles (total)4
Release characteristicOther
Rated impulse withstand voltage Uimp8kV
Rated current2A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles4
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Current limiting class3
Frequency0 - 0Hz
Power loss8.8W
Over voltage category3
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Pollution degree2
Flush-mounted installationYes
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0 - 70mm²
Degree of protection (IP)IP20
Width in number of modular spacings6
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030050R0001 | S804S-UCK2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Rated insulation voltage Ui

1500V

Number of poles (total)

4

Release characteristic

Other

Rated impulse withstand voltage Uimp

8kV

Rated current

2A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

4

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Current limiting class

3

Frequency

0 .. 0Hz

Power loss

8.8W

Over voltage category

3

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

6