Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Number of poles (total)2
Release characteristicOther
Rated insulation voltage Ui1500V
Number of protected poles2
Rated current8A
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated voltage-V
Power loss3.4W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency0 - 0Hz
Width in number of modular spacings3
Flush-mounted installationYes
Degree of protection (IP)IP20
Over voltage category3
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Pollution degree2
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030055R0001 | S802S-UCK8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of poles (total)

2

Release characteristic

Other

Rated insulation voltage Ui

1500V

Number of protected poles

2

Rated current

8A

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated voltage

-V

Power loss

3.4W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

0 .. 0Hz

Width in number of modular spacings

3

Flush-mounted installation

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Pollution degree

2

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.