Technical specifications

Rated voltage480V
Built-in depth102mm
Width in number of modular spacings36
Frequency50 - 60Hz
Over voltage category3
Rated current30A
Release characteristicK
Voltage typeOther
Current limiting class3
Rated insulation voltage Ui500V
Pollution degree2
Power loss5.4W
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Degree of protection (IP)IP20
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000116R0001 | SUP402M-K30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

480V

Built-in depth

102mm

Width in number of modular spacings

36

Frequency

50 .. 60Hz

Over voltage category

3

Rated current

30A

Release characteristic

K

Voltage type

Other

Current limiting class

3

Rated insulation voltage Ui

500V

Pollution degree

2

Power loss

5.4W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Degree of protection (IP)

IP20

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²