Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage480V
Voltage typeOther
Built-in depth102mm
Rated current4A
Rated insulation voltage Ui500V
Power loss3.9W
Pollution degree2
Degree of protection (IP)IP20
Release characteristicK
Over voltage category3
Explosion-proofNo
Frequency50 - 60Hz
Current limiting class3
Width in number of modular spacings54
Number of protected poles3
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000121R0001 | SUP403M-K4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

480V

Voltage type

Other

Built-in depth

102mm

Rated current

4A

Rated insulation voltage Ui

500V

Power loss

3.9W

Pollution degree

2

Degree of protection (IP)

IP20

Release characteristic

K

Over voltage category

3

Explosion-proof

Frequency

50 .. 60Hz

Current limiting class

3

Width in number of modular spacings

54

Number of protected poles

3

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.