Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Number of protected poles3
Rated current16A
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Rated voltage480V
Release characteristicK
Built-in depth102mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Power loss5.7W
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Frequency50 - 60Hz
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree2
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Width in number of modular spacings54
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000126R0001 | SUP403M-K16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated voltage

480V

Release characteristic

K

Built-in depth

102mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

5.7W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Width in number of modular spacings

54

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.