Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Current limiting class3
Width in number of modular spacings18
Over voltage category3
Voltage typeOther
Degree of protection (IP)IP20
Rated voltage240V
Rated current10A
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree2
Number of protected poles1
Release characteristicK
Concurrently switching neutral conductorNo
Built-in depth102mm
Explosion-proofNo
Power loss1.3W
Frequency50 - 60Hz
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000147R0001 | SUP401M-K10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Current limiting class

3

Width in number of modular spacings

18

Over voltage category

3

Voltage type

Other

Degree of protection (IP)

IP20

Rated voltage

240V

Rated current

10A

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

2

Number of protected poles

1

Release characteristic

K

Concurrently switching neutral conductor

Built-in depth

102mm

Explosion-proof

Power loss

1.3W

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.