Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth102mm
Rated voltage240V
Rated insulation voltage Ui500V
Release characteristicK
Frequency50 - 60Hz
Rated current13A
Explosion-proofNo
Width in number of modular spacings18
Number of protected poles1
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category3
Power loss1.7W
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Pollution degree2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000148R0001 | SUP401M-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

102mm

Rated voltage

240V

Rated insulation voltage Ui

500V

Release characteristic

K

Frequency

50 .. 60Hz

Rated current

13A

Explosion-proof

Width in number of modular spacings

18

Number of protected poles

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Power loss

1.7W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Concurrently switching neutral conductor

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.