Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth102mm
Number of poles (total)1
Release characteristicK
Number of protected poles1
Rated voltage240V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss2W
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated current20A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Current limiting class3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Over voltage category3
Additional equipment possibleYes
Width in number of modular spacings18
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000150R0001 | SUP401M-K20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

102mm

Number of poles (total)

1

Release characteristic

K

Number of protected poles

1

Rated voltage

240V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

2W

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated current

20A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Current limiting class

3

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

18

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.