Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current30A
Number of protected poles1
Built-in depth102mm
Number of poles (total)1
Release characteristicK
Rated voltage240V
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss2.7W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Current limiting class3
Voltage typeOther
Flush-mounted installationNo
Pollution degree2
Over voltage category3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Width in number of modular spacings18
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000152R0001 | SUP401M-K30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

30A

Number of protected poles

1

Built-in depth

102mm

Number of poles (total)

1

Release characteristic

K

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

2.7W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Current limiting class

3

Voltage type

Other

Flush-mounted installation

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Width in number of modular spacings

18

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.