2CCG000153R0001 | SUP401M-K5

Code: 1999472

ManufacturerRAZNO
Catalog number2CCG000153R0001
Type
EAN code7612271506865

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

102mm

Release characteristic

K

Voltage type

Other

Number of protected poles

1

Rated voltage

240V

Rated current

5A

Rated insulation voltage Ui

500V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Power loss

1.1W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

1

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Explosion-proof

No

Additional equipment possible

Yes

Over voltage category

3

Width in number of modular spacings

18

Connectable conductor cross section multi-wired

0.75 - 25mm²

Pollution degree

2

Ambient temperature during operating

-25 - 60°C


Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000153R0001 | SUP401M-K5

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

102mm

Release characteristic

K

Voltage type

Other

Number of protected poles

1

Rated voltage

240V

Rated current

5A

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Power loss

1.1W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

1

Flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Additional equipment possible

Over voltage category

3

Width in number of modular spacings

18

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C