Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth91mm
Release characteristicC
Number of protected poles2
Number of poles (total)2
Rated current16A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Power loss3.8W
Current limiting class3
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo
Pollution degree3
Concurrently switching neutral conductorNo
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Over voltage category3
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000372R0001 | S402P-C16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Release characteristic

C

Number of protected poles

2

Number of poles (total)

2

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

3.8W

Current limiting class

3

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Pollution degree

3

Concurrently switching neutral conductor

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.