Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated current40A
Release characteristicC
Rated voltage415V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth91mm
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Power loss7.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Current limiting class3
Flush-mounted installationNo
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings2
Pollution degree3
Additional equipment possibleYes
Over voltage category3
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000377R0001 | S402P-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated current

40A

Release characteristic

C

Rated voltage

415V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

91mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Power loss

7.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Current limiting class

3

Flush-mounted installation

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

2

Pollution degree

3

Additional equipment possible

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.