Aleta.hr
Main Product Image

2CCG000378R0001 | S402P-C50

Code: 1999538

ManufacturerABB
Catalog number2CCG000378R0001
EAN code7612271509514

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Rated current50A
Release characteristicC
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Number of poles (total)2
Voltage typeOther
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Frequency50 - 60Hz
Power loss7.4W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth91mm
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings2
Additional equipment possibleYes
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000378R0001 | S402P-C50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated current

50A

Release characteristic

C

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Number of poles (total)

2

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 .. 60Hz

Power loss

7.4W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

91mm

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

2

Additional equipment possible

Flush-mounted installation

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.