Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Width in number of modular spacings2
Built-in depth91mm
Voltage typeOther
Rated voltage415V
Frequency50 - 60Hz
Pollution degree3
Power loss11W
Rated insulation voltage Ui440V
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Number of protected poles2
Degree of protection (IP)IP20
Current limiting class3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
Rated current63A
Release characteristicC
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000379R0001 | S402P-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Width in number of modular spacings

2

Built-in depth

91mm

Voltage type

Other

Rated voltage

415V

Frequency

50 .. 60Hz

Pollution degree

3

Power loss

11W

Rated insulation voltage Ui

440V

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Number of protected poles

2

Degree of protection (IP)

IP20

Current limiting class

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV

Rated current

63A

Release characteristic

C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.