Aleta.hr
Main Product Image

2CCG000383R0001 | S403P-C6

Code: 1999543

ManufacturerABB
Catalog number2CCG000383R0001
EAN code7612271509569

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated voltage415V
Voltage typeOther
Power loss4.8W
Number of protected poles3
Rated current6A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui440V
Release characteristicC
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth91mm
Frequency50 - 60Hz
Flush-mounted installationNo
Over voltage category3
Width in number of modular spacings3
Pollution degree3
Degree of protection (IP)IP20
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000383R0001 | S403P-C6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated voltage

415V

Voltage type

Other

Power loss

4.8W

Number of protected poles

3

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

440V

Release characteristic

C

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

91mm

Frequency

50 .. 60Hz

Flush-mounted installation

Over voltage category

3

Width in number of modular spacings

3

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.