Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Rated current20A
Over voltage category3
Rated insulation voltage Ui440V
Voltage typeOther
Built-in depth91mm
Current limiting class3
Release characteristicC
Frequency50 - 60Hz
Rated voltage415V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss6W
Number of protected poles3
Additional equipment possibleYes
Width in number of modular spacings3
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Number of poles (total)3
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000389R0001 | S403P-C20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Rated current

20A

Over voltage category

3

Rated insulation voltage Ui

440V

Voltage type

Other

Built-in depth

91mm

Current limiting class

3

Release characteristic

C

Frequency

50 .. 60Hz

Rated voltage

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

6W

Number of protected poles

3

Additional equipment possible

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Number of poles (total)

3

Rated impulse withstand voltage Uimp

4kV