Aleta.hr
Main Product Image

2CCG000404R0001 | S403P-C20NP

Code: 1999564

ManufacturerABB
Catalog number2CCG000404R0001
EAN code7612271509750

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth91mm
Release characteristicC
Number of protected poles4
Rated current20A
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Power loss8W
Width in number of modular spacings4
Pollution degree3
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Over voltage category3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Flush-mounted installationNo
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000404R0001 | S403P-C20NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Release characteristic

C

Number of protected poles

4

Rated current

20A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Power loss

8W

Width in number of modular spacings

4

Pollution degree

3

Additional equipment possible

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Flush-mounted installation

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.