Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current63A
Built-in depth91mm
Pollution degree3
Over voltage category3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Explosion-proofNo
Width in number of modular spacings1
Rated voltage240V
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of protected poles1
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Power loss5.5W
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Release characteristicB
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000409R0001 | S401P-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

63A

Built-in depth

91mm

Pollution degree

3

Over voltage category

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Explosion-proof

Width in number of modular spacings

1

Rated voltage

240V

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of protected poles

1

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Power loss

5.5W

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Release characteristic

B

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA