Aleta.hr
Main Product Image

2CCG000420R0001 | S401P-B2NP

Code: 1999580

ManufacturerABB
Catalog number2CCG000420R0001
EAN code7612271508555

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Number of protected poles2
Rated current2A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Built-in depth91mm
Release characteristicB
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated voltage240V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss2.6W
Frequency50 - 60Hz
Current limiting class3
Pollution degree3
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Over voltage category3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Width in number of modular spacings2
Explosion-proofNo
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000420R0001 | S401P-B2NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Number of protected poles

2

Rated current

2A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Built-in depth

91mm

Release characteristic

B

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated voltage

240V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

2.6W

Frequency

50 .. 60Hz

Current limiting class

3

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Explosion-proof

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.