Aleta.hr
Main Product Image

2CCG000423R0001 | S401P-K40

Code: 1999583

ManufacturerABB
Catalog number2CCG000423R0001
EAN code7612271509927

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Number of protected poles1
Built-in depth91mm
Rated impulse withstand voltage Uimp4kV
Release characteristicK
Rated voltage240V
Rated current40A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Voltage typeOther
Power loss3.6W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Additional equipment possibleYes
Flush-mounted installationNo
Width in number of modular spacings1
Over voltage category3
Pollution degree3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000423R0001 | S401P-K40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Number of protected poles

1

Built-in depth

91mm

Rated impulse withstand voltage Uimp

4kV

Release characteristic

K

Rated voltage

240V

Rated current

40A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Voltage type

Other

Power loss

3.6W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Additional equipment possible

Flush-mounted installation

Width in number of modular spacings

1

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof