Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240V
Voltage typeOther
Release characteristicK
Rated current3A
Frequency50 - 60Hz
Built-in depth91mm
Width in number of modular spacings2
Pollution degree3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Over voltage category3
Explosion-proofNo
Current limiting class3
Power loss2.4W
Number of protected poles2
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000427R0001 | S401P-K3NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Voltage type

Other

Release characteristic

K

Rated current

3A

Frequency

50 .. 60Hz

Built-in depth

91mm

Width in number of modular spacings

2

Pollution degree

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Over voltage category

3

Explosion-proof

Current limiting class

3

Power loss

2.4W

Number of protected poles

2

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.