Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth91mm
Release characteristicK
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated current32A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated voltage240V
Power loss6W
Number of protected poles2
Current limiting class3
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings2
Pollution degree3
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Connectable conductor cross section solid-core0.75 - 35mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000437R0001 | S401P-K32NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Release characteristic

K

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated current

32A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

240V

Power loss

6W

Number of protected poles

2

Current limiting class

3

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

2

Pollution degree

3

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.