Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current13A
Release characteristicK
Frequency50 - 60Hz
Built-in depth91mm
Rated voltage415V
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Power loss3.4W
Width in number of modular spacings2
Explosion-proofNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000448R0001 | S402P-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

13A

Release characteristic

K

Frequency

50 .. 60Hz

Built-in depth

91mm

Rated voltage

415V

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Power loss

3.4W

Width in number of modular spacings

2

Explosion-proof

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.