  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Built-in depth91mm
Rated voltage415V
Release characteristicK
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current16A
Power loss3.8W
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Voltage typeOther
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings2
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000449R0001 | S402P-K16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Built-in depth

91mm

Rated voltage

415V

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

16A

Power loss

3.8W

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Voltage type

Other

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

2

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Additional equipment possible