Aleta.hr
Main Product Image

2CCG000466R0001 | S403P-K20

Code: 1999626

ManufacturerABB
Catalog number2CCG000466R0001
EAN code7612271510312

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Voltage typeOther
Rated voltage415V
Power loss6W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Rated current20A
Built-in depth91mm
Number of poles (total)3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Explosion-proofNo
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings3
Over voltage category3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000466R0001 | S403P-K20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Voltage type

Other

Rated voltage

415V

Power loss

6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Rated current

20A

Built-in depth

91mm

Number of poles (total)

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Explosion-proof

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

3

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.