Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Rated voltage415V
Built-in depth91mm
Rated insulation voltage Ui440V
Release characteristicK
Voltage typeOther
Rated impulse withstand voltage Uimp4kV
Rated current40A
Number of protected poles3
Power loss10.8W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Pollution degree3
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000469R0001 | S403P-K40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Rated voltage

415V

Built-in depth

91mm

Rated insulation voltage Ui

440V

Release characteristic

K

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated current

40A

Number of protected poles

3

Power loss

10.8W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Pollution degree

3

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.