Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth91mm
Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Rated voltage415V
Over voltage category3
Release characteristicK
Rated current2A
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings4
Number of poles (total)4
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Power loss5.2W
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000472R0001 | S403P-K2NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Rated voltage

415V

Over voltage category

3

Release characteristic

K

Rated current

2A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Number of poles (total)

4

Concurrently switching neutral conductor

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Power loss

5.2W

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.