Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Release characteristicB
Number of protected poles2
Rated current10A
Built-in depth91mm
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Power loss2.6W
Additional equipment possibleYes
Degree of protection (IP)IP20
Over voltage category3
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000476R0001 | S401P-B10NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Release characteristic

B

Number of protected poles

2

Rated current

10A

Built-in depth

91mm

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

2.6W

Additional equipment possible

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.