Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Number of protected poles4
Rated insulation voltage Ui440V
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Built-in depth91mm
Rated current10A
Rated voltage415V
Voltage typeOther
Power loss5.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Flush-mounted installationNo
Over voltage category3
Concurrently switching neutral conductorYes
Explosion-proofNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000479R0001 | S403P-K10NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Number of protected poles

4

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Built-in depth

91mm

Rated current

10A

Rated voltage

415V

Voltage type

Other

Power loss

5.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.