Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current20A
Frequency50 - 60Hz
Rated voltage415V
Voltage typeOther
Release characteristicK
Built-in depth91mm
Width in number of modular spacings4
Current limiting class3
Rated insulation voltage Ui440V
Pollution degree3
Explosion-proofNo
Degree of protection (IP)IP20
Over voltage category3
Power loss8W
Number of protected poles4
Number of poles (total)4
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000482R0001 | S403P-K20NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

20A

Frequency

50 .. 60Hz

Rated voltage

415V

Voltage type

Other

Release characteristic

K

Built-in depth

91mm

Width in number of modular spacings

4

Current limiting class

3

Rated insulation voltage Ui

440V

Pollution degree

3

Explosion-proof

Degree of protection (IP)

IP20

Over voltage category

3

Power loss

8W

Number of protected poles

4

Number of poles (total)

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.