Aleta.hr
Main Product Image

2CCG000487R0001 | S401P-B13NP

Code: 1999647

ManufacturerABB
Catalog number2CCG000487R0001
EAN code7612271508616

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Number of protected poles2
Built-in depth91mm
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Voltage typeOther
Rated voltage240V
Rated current13A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss3.4W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Release characteristicB
Flush-mounted installationNo
Degree of protection (IP)IP20
Pollution degree3
Width in number of modular spacings2
Additional equipment possibleYes
Explosion-proofNo
Over voltage category3
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000487R0001 | S401P-B13NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Built-in depth

91mm

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated voltage

240V

Rated current

13A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.4W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Release characteristic

B

Flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

2

Additional equipment possible

Explosion-proof

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.