Aleta.hr
Main Product Image

2CCG000489R0001 | S401P-B16NP

Code: 1999649

ManufacturerRAZNO
Catalog number2CCG000489R0001
Type
EAN code7612271508623

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Number of protected poles

2

Rated voltage

240V

Number of poles (total)

2

Rated current

16A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.8W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 - 60Hz

Release characteristic

B

Additional equipment possible

Yes

Concurrently switching neutral conductor

Yes

Ambient temperature during operating

-25 - 60°C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Pollution degree

3

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 35mm²

Over voltage category

3

Flush-mounted installation

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000489R0001 | S401P-B16NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Number of protected poles

2

Rated voltage

240V

Number of poles (total)

2

Rated current

16A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.8W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 .. 60Hz

Release characteristic

B

Additional equipment possible

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.