Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated current20A
Rated voltage240V
Rated insulation voltage Ui440V
Voltage typeOther
Frequency50 - 60Hz
Built-in depth91mm
Width in number of modular spacings2
Current limiting class3
Over voltage category3
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Degree of protection (IP)IP20
Number of protected poles2
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Power loss4W
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000490R0001 | S401P-B20NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated current

20A

Rated voltage

240V

Rated insulation voltage Ui

440V

Voltage type

Other

Frequency

50 .. 60Hz

Built-in depth

91mm

Width in number of modular spacings

2

Current limiting class

3

Over voltage category

3

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Degree of protection (IP)

IP20

Number of protected poles

2

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Power loss

4W

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible