Aleta.hr
Main Product Image

2CCG000503R0001 | S402P-B13

Code: 1999663

ManufacturerRAZNO
Catalog number2CCG000503R0001
Type
EAN code7612271508753

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of poles (total)

2

Number of protected poles

2

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Current limiting class

3

Power loss

3.4W

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Over voltage category

3

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Pollution degree

3

Ambient temperature during operating

-25 - 60°C

Explosion-proof

No

Additional equipment possible

Yes

Connectable conductor cross section multi-wired

0.75 - 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 - 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000503R0001 | S402P-B13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Number of poles (total)

2

Number of protected poles

2

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Current limiting class

3

Power loss

3.4W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

3

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.