Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240V
Voltage typeOther
Built-in depth91mm
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Power loss6W
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Number of protected poles2
Additional equipment possibleYes
Pollution degree3
Degree of protection (IP)IP20
Current limiting class3
Concurrently switching neutral conductorNo
Rated current32A
Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000507R0001 | S402P-B32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Voltage type

Other

Built-in depth

91mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Power loss

6W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Number of protected poles

2

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Current limiting class

3

Concurrently switching neutral conductor

Rated current

32A

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.