Technical specifications

Number of protected poles

3

Release characteristic

B

Built-in depth

91mm

Rated insulation voltage Ui

440V

Rated current

10A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

3.9W

Current limiting class

3

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated voltage

415V

Additional equipment possible

Yes

Flush-mounted installation

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

Over voltage category

3

Ambient temperature during operating

-25 - 60°C

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section solid-core

0.75 - 35mm²

Width in number of modular spacings

3

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000517R0001 | S403P-B10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Release characteristic

B

Built-in depth

91mm

Rated insulation voltage Ui

440V

Rated current

10A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

3.9W

Current limiting class

3

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated voltage

415V

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

3

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.