Aleta.hr
Main Product Image

2CCG000533R0001 | S403P-B10NP

Code: 1999693

ManufacturerABB
Catalog number2CCG000533R0001
EAN code7612271509026

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated voltage240V
Rated impulse withstand voltage Uimp4kV
Built-in depth91mm
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Current limiting class3
Number of protected poles4
Frequency50 - 60Hz
Power loss5.2W
Number of poles (total)4
Rated current10A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Flush-mounted installationNo
Pollution degree3
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Over voltage category3
Additional equipment possibleYes
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings4
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000533R0001 | S403P-B10NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated voltage

240V

Rated impulse withstand voltage Uimp

4kV

Built-in depth

91mm

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Number of protected poles

4

Frequency

50 .. 60Hz

Power loss

5.2W

Number of poles (total)

4

Rated current

10A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Flush-mounted installation

Pollution degree

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

4

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.