  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Frequency50 - 60Hz
Rated voltage415V
Rated insulation voltage Ui440V
Built-in depth91mm
Explosion-proofNo
Pollution degree3
Over voltage category3
Number of protected poles4
Concurrently switching neutral conductorYes
Current limiting class3
Width in number of modular spacings4
Power loss9.2W
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated impulse withstand voltage Uimp4kV
Rated current25A
Release characteristicB
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000537R0001 | S403P-B25NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Frequency

50 .. 60Hz

Rated voltage

415V

Rated insulation voltage Ui

440V

Built-in depth

91mm

Explosion-proof

Pollution degree

3

Over voltage category

3

Number of protected poles

4

Concurrently switching neutral conductor

Current limiting class

3

Width in number of modular spacings

4

Power loss

9.2W

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Release characteristic

B

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA