Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated voltage240V
Rated current63A
Built-in depth91mm
Frequency50 - 60Hz
Voltage typeOther
Rated insulation voltage Ui440V
Number of poles (total)4
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Pollution degree3
Concurrently switching neutral conductorYes
Width in number of modular spacings4
Ambient temperature during operating-25 - 60°C
Number of protected poles4
Explosion-proofNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Power loss22W

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000542R0001 | S403P-B63NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated voltage

240V

Rated current

63A

Built-in depth

91mm

Frequency

50 .. 60Hz

Voltage type

Other

Rated insulation voltage Ui

440V

Number of poles (total)

4

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Pollution degree

3

Concurrently switching neutral conductor

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

4

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Power loss

22W