Technical specifications

Number of poles (total)1
Release characteristicC
Rated impulse withstand voltage Uimp4kV
Rated voltage240V
Rated current20A
Number of protected poles1
Rated insulation voltage Ui440V
Built-in depth91mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Frequency50 - 60Hz
Power loss2W
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V30kA
Flush-mounted installationNo
Width in number of modular spacings1
Pollution degree3
Over voltage category3
Additional equipment possibleYes
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000551R0001 | S401P-C20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Rated current

20A

Number of protected poles

1

Rated insulation voltage Ui

440V

Built-in depth

91mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Frequency

50 .. 60Hz

Power loss

2W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

30kA

Flush-mounted installation

Width in number of modular spacings

1

Pollution degree

3

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.