Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Number of poles (total)1
Rated voltage240V
Rated insulation voltage Ui440V
Rated current50A
Built-in depth91mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Power loss3.7W
Current limiting class3
Release characteristicC
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 60°C
Over voltage category3
Width in number of modular spacings1
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCG000556R0001 | S401P-C50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

1

Rated voltage

240V

Rated insulation voltage Ui

440V

Rated current

50A

Built-in depth

91mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Power loss

3.7W

Current limiting class

3

Release characteristic

C

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Width in number of modular spacings

1

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.