Technical specifications

Built-in depth69mm
Rated voltage415V
Rated current13A
Voltage typeAC
Release characteristicC
Rated fault current0.03A
Surge current capacity3kA
Rated insulation voltage Ui500V
Leakage current typeA
Width in number of modular spacings4
Current limiting class3
Over voltage category3
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Connectable conductor cross section solid-core- - -mm²
With interlocking deviceNo
Concurrently switching neutral conductorYes
Power loss-W
Suitable for flush-mounted installationNo
Number of poles (total)4
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Degree of protection (IP)IP2X
Number of protected poles3
Anti-nuisance tripping versionNo
Frequency50/60 Hz
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL463111E0134 | FS463E-C13/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

415V

Rated current

13A

Voltage type

AC

Release characteristic

C

Rated fault current

0.03A

Surge current capacity

3kA

Rated insulation voltage Ui

500V

Leakage current type

A

Width in number of modular spacings

4

Current limiting class

3

Over voltage category

3

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Connectable conductor cross section solid-core

- .. -mm²

With interlocking device

Concurrently switching neutral conductor

Power loss

-W

Suitable for flush-mounted installation

Number of poles (total)

4

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Degree of protection (IP)

IP2X

Number of protected poles

3

Anti-nuisance tripping version

Frequency

50/60 Hz

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.