Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage415V
Release characteristicC
Rated current16A
Rated fault current0.03A
Built-in depth69mm
Rated insulation voltage Ui500V
Over voltage category3
Power loss-W
Width in number of modular spacings4
Pollution degree2
Surge current capacity3kA
Frequency50/60 Hz
Leakage current typeA
Current limiting class3
Degree of protection (IP)IP2X
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorYes
Number of protected poles3
With interlocking deviceNo
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Number of poles (total)4
Connectable conductor cross section solid-core- - -mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL463111E0164 | FS463E-C16/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

415V

Release characteristic

C

Rated current

16A

Rated fault current

0.03A

Built-in depth

69mm

Rated insulation voltage Ui

500V

Over voltage category

3

Power loss

-W

Width in number of modular spacings

4

Pollution degree

2

Surge current capacity

3kA

Frequency

50/60 Hz

Leakage current type

A

Current limiting class

3

Degree of protection (IP)

IP2X

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Number of protected poles

3

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Number of poles (total)

4

Connectable conductor cross section solid-core

- .. -mm²

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version