Technical specifications

Rated current32A
Built-in depth69mm
Voltage typeAC
Rated voltage415V
Rated fault current0.03A
Leakage current typeA
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorYes
Rated insulation voltage Ui500V
Number of poles (total)4
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Degree of protection (IP)IP2X
Rated impulse withstand voltage Uimp4kV
Current limiting class3
Frequency50/60 Hz
Power loss-W
Surge current capacity3kA
Pollution degree2
Number of protected poles3
Over voltage category3
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Release characteristicC
With interlocking deviceNo
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section solid-core- - -mm²
Disconnection characteristicUndelayed
Width in number of modular spacings4
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL463111E0324 | FS463E-C32/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

32A

Built-in depth

69mm

Voltage type

AC

Rated voltage

415V

Rated fault current

0.03A

Leakage current type

A

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Rated insulation voltage Ui

500V

Number of poles (total)

4

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Degree of protection (IP)

IP2X

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Frequency

50/60 Hz

Power loss

-W

Surge current capacity

3kA

Pollution degree

2

Number of protected poles

3

Over voltage category

3

Flush-mounted installation

Anti-nuisance tripping version

Release characteristic

C

With interlocking device

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section solid-core

- .. -mm²

Disconnection characteristic

Undelayed

Width in number of modular spacings

4

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.