Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage240V
Release characteristicC
Rated current10A
Built-in depth91mm
Current limiting class3
Over voltage category3
Surge current capacity0.25kA
Pollution degree2
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-225kA
Power loss1.9W
Leakage current typeA
Number of protected poles1
Width in number of modular spacings2
Degree of protection (IP)IP20
Suitable for flush-mounted installationYes
Frequency50/60 Hz
Rated fault current0.1A
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
With interlocking deviceYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)2
Flush-mounted installationYes
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL562120E0104 | FS401M-C10/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

240V

Release characteristic

C

Rated current

10A

Built-in depth

91mm

Current limiting class

3

Over voltage category

3

Surge current capacity

0.25kA

Pollution degree

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Power loss

1.9W

Leakage current type

A

Number of protected poles

1

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Frequency

50/60 Hz

Rated fault current

0.1A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

2

Flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.