Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Degree of protection (IP)IP20
Rated current32A
Built-in depth91mm
Width in number of modular spacings2
Frequency50/60 Hz
Concurrently switching neutral conductorYes
Over voltage category3
Current limiting class3
Rated voltage240V
Surge current capacity3kA
Rated insulation voltage Ui500V
Suitable for flush-mounted installationNo
Number of protected poles1
Voltage typeAC
Leakage current typeF
Rated fault current0.03A
Connectable conductor cross section solid-core- - -mm²
Pollution degree2
Power loss5.6W
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
With interlocking deviceYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL562310E1325 | FS401MK-B32/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Degree of protection (IP)

IP20

Rated current

32A

Built-in depth

91mm

Width in number of modular spacings

2

Frequency

50/60 Hz

Concurrently switching neutral conductor

Over voltage category

3

Current limiting class

3

Rated voltage

240V

Surge current capacity

3kA

Rated insulation voltage Ui

500V

Suitable for flush-mounted installation

Number of protected poles

1

Voltage type

AC

Leakage current type

F

Rated fault current

0.03A

Connectable conductor cross section solid-core

- .. -mm²

Pollution degree

2

Power loss

5.6W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

10kA