Aleta.hr
Main Product Image

2CCL563310E1324 | FS402MK-C13/0.03

Code: 1999801

ManufacturerABB
Catalog number2CCL563310E1324
EAN code7612271473402

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installationNo
Number of poles (total)4
Number of protected poles3
Rated voltage400V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current32A
Rated fault current0.3A
Leakage current typeF
Power loss-W
Current limiting class3
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Surge current capacity3kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicD
Concurrently switching neutral conductorYes
With interlocking deviceYes
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings4
Flush-mounted installationNo
Built-in depth76mm
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL563310E1324 | FS402MK-C13/0.03

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Number of poles (total)

4

Number of protected poles

3

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated fault current

0.3A

Leakage current type

F

Power loss

-W

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

D

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

4

Flush-mounted installation

Built-in depth

76mm

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.